Tool · Water
Water softener sizing calculator
Most softeners are sized by guesswork. Enter your numbers and this shows the capacity you need, and the math behind it.
Your result
–grain softener (recommended)
| Effective hardness | – |
|---|---|
| Grains removed per day | – |
| Grains needed per regeneration | – |
| Smallest size at max salt | – |
| Estimated salt use | – |
How this works
- Effective hardness = hardness in gpg + 4 × iron (ppm). Iron uses up softener capacity, and adding about 4 gpg per ppm of iron is a standard rule of thumb. Hardness in mg/L is converted at 17.1 mg/L per grain.
- Grains per day = people × gallons per person per day × effective hardness.
- Grains per regeneration = grains per day × days between regenerations.
- Recommended size. A softener's rated capacity (say 32,000 grains) assumes the maximum salt dose. Run at a salt-efficient setting, it delivers roughly 60–65% of that. We recommend the smallest common size whose efficient capacity covers your cycle, so you don't burn extra salt. The "max salt" size is the bare minimum.
- Salt estimate assumes about 3,300 grains removed per pound of salt at an efficient setting. Real numbers vary with the valve and settings.
Do you even need one? The Minnesota Department of Health says a softener may be worth it when hardness is above about 7 grains per gallon (120 mg/L), mostly to protect appliances and reduce scale. Softening is a choice, not a health requirement.
This calculator is a planning tool. Flow rate, plumbing size and very high iron or manganese can change the right answer, and a water test is always worth it.